86 MPCMM0001 Chassis Management Module Software Technical Product Specification
The Command Line Interface (CLI)
Table 27. Dataitem Keywords for Cmm Location (Sheet 1 of 7)
dataitem Description
Get/
Set
CLI Get Output Valid Set Values
listlocations
Used to find out all the
locations that can be queried.
This list can contain both
present and non-present
locations.
Get
All possible locations in the shelf e.g.
“cmm
blade1
blade2
blade3
blade4
blade5
blade6
blade7
blade8
blade9
blade10
blade11
blade12
blade13
blade14
FanTray
PEM1
PEM2
chassis
system”
N/A
listpresent
Used to query the locations
that are currently present in
the shelf that the CMM can
communicate with.
Get
All the present locations in the shelf. It
is the subset of listlocation. e.g.:
“cmm
blade1
blade2
FanTray
PEM1
PEM2
chassis
system”
N/A
clearsel
Clears the event log of the
entire shelf.
cmmset -d clearsel -v clear
Set N/A clear
powerbudget
Get information about the
overall power budget, how
much is used, how much
available
Get
"Shelf Power Budget Distribution:
Feed #1 = A Watts
Feed #2 = B Watts
Feed #3 = B Watts
...
Feed #N = D Watts"
N/A