Juniper Networks MX240 Network Router User Manual


 
3 Empty
4 Empty
5 Online 42 6 0 1024 16 57
For more detailed output, add the detail option. The following example does not
specify a slot number, which is optional:
user@host> show chassis fpc detail
Slot 1 information:
State Online
Temperature 33 degrees C / 91 degrees F
Total CPU DRAM 1024 MB
Total RLDRAM 256 MB
Total DDR DRAM 4096 MB
Start time: 2007-12-06 11:33:01 PST
Uptime: 4 hours, 34 minutes, 48 seconds
Slot 2 information:
State Online
Temperature 33 degrees C / 91 degrees F
Total CPU DRAM 1024 MB
Total RLDRAM 256 MB
Total DDR DRAM 4096 MB
Start time: 2007-12-06 11:33:05 PST
Uptime: 4 hours, 34 minutes, 44 seconds
Issue the CLI show chassis fpc pic-status command. The DPC slots are numbered
1/0, 1, and 2, left to right:
user@host> show chassis fpc pic-status
Slot 0 Online DPCE 4x 10GE R
PIC 0 Online 1x 10GE(LAN/WAN)
PIC 1 Online 1x 10GE(LAN/WAN)
PIC 2 Online 1x 10GE(LAN/WAN)
PIC 3 Online 1x 10GE(LAN/WAN)
Slot 1 Online DPCE 40x 1GE R
PIC 0 Online 10x 1GE(LAN)
PIC 1 Online 10x 1GE(LAN)
PIC 2 Online 10x 1GE(LAN)
PIC 3 Online 10x 1GE(LAN)
Slot 2 Online DPCE 40x 1GE R
PIC 0 Online 10x 1GE(LAN)
PIC 1 Online 10x 1GE(LAN)
PIC 2 Online 10x 1GE(LAN)
PIC 3 Online 10x 1GE(LAN)
For further description of the output from the command, see the JUNOS System
Basics and Services Command Reference.
Maintaining Packet Forwarding Engine Components 73
Chapter 11: Maintaining Hardware Components