Juniper Networks MX240 Network Router User Manual


 
Total RLDRAM 256 MB
Total DDR DRAM 4096 MB
Start time: 2007-12-06 11:33:01 PST
Uptime: 4 hours, 34 minutes, 48 seconds
Slot 2 information:
State Online
Temperature 33 degrees C / 91 degrees F
Total CPU DRAM 1024 MB
Total RLDRAM 256 MB
Total DDR DRAM 4096 MB
Start time: 2007-12-06 11:33:05 PST
Uptime: 4 hours, 34 minutes, 44 seconds
For further description of the output from the commands, see the JUNOS System
Basics and Services Command Reference.
If a DPC is not functioning normally, follow these guidelines to troubleshoot the DPC:
Make sure the DPC is properly seated in the midplane. Check that each ejector
handle has been turned clockwise and is tight.
Troubleshooting the Power System
To verify that a power supply is functioning normally, perform the following steps:
Check the LEDs on each power supply faceplate.
If an AC power supply is correctly installed and functioning normally, the
AC OK and DC OK LEDs light steadily, and the PS FAIL LED is not lit. For more
information about the LEDs, see AC Power Supply LEDs on page 22.
If a DC power supply is correctly installed and functioning normally, the
PWR OK, BRKR ON, and INPUT OK LEDs light green steadily. For more
information about the LEDs, see DC Power Supply LEDs on page 24.
Issue the CLI show chassis environment pem command to check the status of
installed power supplies. As shown in the sample output, the value Online in the
rows labeled State indicates that the power supplies in slots 0 and 1 are
functioning normally:
user@host> show chassis environment pem
PEM 0 status:
State Online
Temperature OK
DC output OK
PEM 2 status:
State Online
84 Troubleshooting the Power System
MX240 Ethernet Services Router Hardware Guide