Lanier LP222cn Printer User Manual


 
Monitoring and Configuring the Printer
200
Protocol configuration
msh> snmp {ip | ipx} {on | off}
Use the following command to set protocols “active” or “inactive”: If you set
a protocol “inactive”, all access settings for that protocol are disabled.
Specify “ip” for TCP/IP, or “ipx” for IPX/SPX.
{on} means “active” and {off} means “inactive”.
IEEE 1394 interface is available for TCP/IP only.
Configuration of protocol for each registration number
msh> snmp “number” active {ip | ipx} {on | off}
To change the protocol of access settings, use the following command.
However, if you have disabled a protocol with the above command, activat-
ing it here has no effect.
Access configuration
msh> snmp “number” {ip/addr | ipx} “address”
You can configure a host address according to the protocol used.
The network interface board accepts requests only from hosts that have
addresses with access types of “read-only” or “read-write”. Enter “0” to
have network interface board accept requests from any host without requir-
ing a specific type of access.
Enter a host address to deliver “trap” access type information to.
To specify TCP/IP, enter “ip” followed by a space, and then the IP address.
To specify IPX/SPX, enter “ipx” followed by a space, the IPX address fol-
lowed by a decimal, and then the MAC address of the network interface
board.
sysLocation configuration
msh> snmp location
Deleting sysLocation
msh> snmp clear location
sysContact setting
msh> snmp contact
read read only
write read and write
trap user is notified of trap messages
Access type Type of access permission