Replacing the Fuser Unit and Transfer Roller Kit
19
Installing the New Waste Toner Pack
1
Remove the new waste toner pack from the drum kit box.
2
Insert the bottom of the waste
toner pack
c
into its installa-
tion position in the printer.
3
Insert the top of the waste
toner pack
d
into its installa-
tion position in the printer until
it is firmly seated.
4
Close the printer’s front cover.
If the waste toner pack is not
correctly installed or the trans-
fer belt right release lever is at
its top position (12 o’clock),
the front cover cannot be
closed.
5
In the Operator Control/Consumables/Items Replaced/Waste Toner
menu, choose Yes to reset the consumables monitoring system.
Replacing the Fuser Unit and Transfer
Roller Kit
WARNING!
The fuser unit can become extremely hot and cause severe
burns. Make sure the unit is cool before handling it.
ACHTUNG! Die Fixiereinheit kann sehr heiß werden, so daß
Verbrennungsgefahr besteht. Bitte lassen Sie die Fixiereinheit einige
Zeit abühlen, bevor Sie diese berühren.
When the fuser is worn out, the message “
REPLACE FUSER UNIT
” appears
and the printer does not print. Replace the fuser kit. After the new fuser kit is
installed, printing automatically resumes.
The fuser kit includes the two items below. When replacing the fuser unit,
replace the transfer roller as well.
EDNord - Istedgade 37A - 9000 Aalborg - telefon 96333500