Mitsubishi Electronics MR-E- A/AG Computer Hardware User Manual


 
5 - 15
5. PARAMETERS
Class No. Symbol Name and function
Initial
value
Unit
Setting
range
Control
mode
42
*DI1 0002
Refer to
Name
and
function
column.
P/S
Expansion parameters 1
Input signal selection 1
Used to assign the control mode changing signal input pins and to set
the clear (CR).
Control change (LOP) input pin
assignment
Used to set the control mode
change signal input connector
pins. Note that this parameter is
made valid when parameter No.
0 is set to select the position/int-
ernal speed change mode.
Set value
0
1
2
Connector pin No.
CN1-4
CN1-3
CN1-5
3CN1-6
Clear (CR) selection
0: Droop pulses are cleared on the
leading edge.
1: While turning on, droop pulses are
always cleared.
4CN1-7
0 0
If forward rotation stroke end (LSP)
or reverse rotation stroke end
(LSN) is assigned to any pin with
parameter No. 48, this setting is
invalid.
P