Mitsubishi FR - S500 Power Supply User Manual


 
8
FR-S520S-0.2K to 1.5K-EC (R)
Power supply
NFB
L
1
N
Motor
IM
Earth
(Ground)
U
V
W
MC
REMARKS
To ensure safety, connect the power input to the inverter via a magnetic
contactor and earth leakage circuit breaker or no-fuse breaker, and use the
magnetic contactor to switch power on-off.
The output is three-phase 200V.
NOTE
To prevent a malfunction due to noise, keep the signal cables more than 10cm
(3.94inches) away from the power cables.
1
.3.2 Layout and wiring of main circuit terminals
FR-S540-0.4K, 0.75K, 1.5K, 2.2K, 3.7K-EC (R)
P1
Jumper
L1 L2 L3 U V W
IM
-
+
Power
supply
Motor
FR-S520S-0.2K, 0.4K, 0.75K-EC (R) FR-S520S-1.5K-EC (R)
P1
U V W
IM
+
-
L1 N
Power
supply
Motor
Jumper
P1
U V W
IM
+
-
L1 N
Jumper
Power
supply
Motor
CAUTION
Connect the motor to U, V, W.
Turning on the forward rotation switch (signal) at this time rotates the motor
counterclockwise when viewed from the load shaft.
For power input wiring, connect L
1
to R/L
1
of the terminal block and N to S/L
2
of
the terminal block.
Do not connect the power supply to U, V and W.