Mitsubishi FR - S500 Power Supply User Manual


 
46
2
.1 Function (Parameter) List
Parameter
Indica-
tion
Name
Setting
Range
Minimum
Setting
Increments
Factory
Setting
<EC
version>
Refer
To:
Cus-
tomer
Setting
0 Torque boost 0 to 15% 0.1%
6%/5%/
4%
(Note 1)
58
1 Maximum frequency 0 to 120Hz 0.1Hz
60Hz
<50Hz>
59
2 Minimum frequency 0 to 120Hz 0.1Hz 0Hz 59
3 Base frequency 0 to 120Hz 0.1Hz
60Hz
<50Hz>
59
4 *
Multi-speed setting
(high speed)
0 to 120Hz 0.1Hz
60Hz
<50Hz>
61
5 *
Multi-speed setting
(middle speed)
0 to 120Hz 0.1Hz 30Hz
61
6 *
Multi-speed setting
(low speed)
0 to 120Hz 0.1Hz 10Hz
61
7 Acceleration time 0 to 999s 0.1s 5s 62
8 Deceleration time 0 to 999s 0.1s 5s 62
9
Electronic thermal O/L
relay
0 to 50A 0.1A
Rated
output
current
64
30 *
Extended function
display selection
0, 1 1 0 72
79
Operation mode
selection
0 to 4, 7, 8 1 0 98
Note 1: The factory setting varies with the inverter capacity: 5% for FR-S540-1.5K and
2.2K, 4% for FR-S540-3.7K.
The extended function parameters are made valid by setting "1" in Pr. 30 "extended
function display selection". (For full information on the way to set Pr. 30, refer to the
instruction manual (basic).)
Func-
tion
Pa-
rame-
ter
Indica-
tion
Name Setting Range
Minimum
Setting
Increments
Factory
Setting
Refer
To:
Cus-
tomer
Setting
10
DC injection
brake
operation
frequency
0 to 120Hz 0.1Hz 3Hz 64
11
DC injection
brake
operation time
0 to 10s 0.1s 0.5s 64
12
DC injection
brake voltage
0 to 15% 0.1% 6% 64
13
Starting
frequency
0 to 60Hz 0.1Hz 0.5Hz 65
Standard operation functions
14
Load pattern
selection
0: For constant-torque
loads,
1: For variable-torque
loads,
2: For vertical lift loads,
3: For vertical lift loads
1066
Pammeter List