1.8.3 Current input selection "AU signal": Setting "4"...................................... 38
1.8.4 Start self-holding selection (STOP signal): Setting "5"........................... 38
1.8.5 Output shut-off (MRS signal): Setting "6"................................................ 39
1.8.6 External thermal relay input: Setting "7".................................................. 39
1.8.7 Jog operation (JOG signal): Setting "9" .................................................. 40
1.8.8 Reset signal: Setting "10"......................................................................... 40
1.8.9 PID control valid terminal: Setting "14".................................................... 41
1.8.10 PU operation/external operation switching: Setting "16" ..................... 41
1.9 Handling of the RS-485 Connector
(Type with RS-485 Communication Function) .......................................41
1.10 Design Information ...............................................................................44
2.
FUNCTIONS
45
2.1 Function (Parameter) List.......................................................................46
2.2 List of Parameters Classified by Purpose of Use...................................56
2.3 Explanation of Functions (Parameters)..................................................58
2.3.1 Torque boost
........................................................................... 58
2.3.2 Maximum and minimum frequency
....................................... 59
2.3.3 Base frequency, Base frequency voltage
.................... 59
2.3.4 Multi-speed operation
to
to ....... 61
2.3.5 Acceleration/deceleration time
................... 62
2.3.6 Electronic overcurrent protection
.................................................... 64
2.3.7 DC injection brake
......................................................... 64
2.3.8 Starting frequency
........................................................................... 65
2.3.9 Load pattern selection
..................................................................... 66
2.3.10 Jog frequency
....................................................................... 67
2.3.11
RUN
key rotation direction selection ............................................. 67
2.3.12 Stall prevention function and current limit function
...................... 68
2.3.13 Stall prevention
............................................................ 69
2.3.14 Acceleration/deceleration pattern
................................................. 71
2.3.15 Extended function display selection
............................................. 72
2.3.16 Frequency jump
to ............................................................... 72
2.3.17 Speed display
................................................................................ 73
2.3.18 Biases and gains of the frequency setting voltage (current)
to .......................................................................... 74
2.3.19 Start-time ground fault detection selection
.................................. 78
2.4 Output Terminal Function Parameters...................................................78
2.4.1 Up-to-frequency sensitivity
.............................................................. 78
2.4.2 Output frequency detection
.................................................... 79
2.5 Current Detection Function Parameters.................................................80
2.5.1 Output current detection functions
........................................ 80
2.5.2 Zero current detection
............................................................ 81
2.6 Display Function Parameters.................................................................82
2.6.1 Monitor display
........................................................................ 82