49
2
Func-
tion
Pa-
rame-
ter
Indica-
tion
Name Setting Range
Minimum
Setting
Increments
Factor
y
Settin
g
<EC
version>
Refer
To:
Cus-
tomer
Settin
g
48
Output current
detection level
0 to 200% 1% 150% 80
49
Output current
detection
signal delay
time
0 to 10s 0.1s 0s 80
50
Zero current
detection level
0 to 200% 1% 5% 81
Current detection
51
Zero current
detection time
0.05 to 1s 0.01s 0.5s 81
52 *
Control panel
display data
selection
0: Output frequency,
1: Output current,
100: Set frequency
during stop/output
frequency during
operation
1082
53 *
Frequency
setting
operation
selection
0: Setting dial
frequency setting
mode
1: Setting dial
potentiometer mode
1083
54 *
FM (AM)
terminal
function
selection
0: Output frequency
monitor
1: Output current
monitor
1082
55 *
Frequency
monitoring
reference
0 to 120Hz 0.1Hz
60Hz
<50Hz>
84
Display functions
56 *
Current
monitoring
reference
0 to 50A 0.1A
Rated
output
current
84
57
Restart
coasting time
0 to 5s, - - - 0.1s - - - 84
Automatic restart
functions
58
Restart
cushion time
0 to 60s 0.1s 1s 84
Additional function
59
Remote
setting
function
selection
0: Without remote
setting function
1: With remote setting
function
With frequency
setting storage
function
2: With remote setting
function
Without frequency
setting storage
function
1086
Pammeter List