Mitsubishi FR - S500 Power Supply User Manual


 
54
Func-
tion
Com-
muni-
cation
Parame-
ter
Indica-
tion
Name Setting Range
Minimum
Setting
Incre-
ments
Factory
Setting
<NA, EC
version>
Refer
To:
Cus-
tomer
Setting
n5 (335)
Number of
communication
retries
0 to 10, - - - 1 1 118
n6 (336)
Communication
check time
interval
0 to 999s, - - - 0.1s
0s
<- - ->
118
n7 (337) Wait time setting 0 to 150ms, - - - 1 - - - 118
n8 (338)
Operation
command write
0: Command write
from computer,
1: Command write
from external
terminal
10130
n9 (339)
Speed command
write
0: Command write
from computer,
1: Command write
from external
terminal
10130
n10
(340)
Link start mode
selection
0: As set in Pr. 79.
1:
Started in
computer link
operation mode.
10131
n11
(341)
CR/LF selection
0: Without CR/LF,
1: With CR,
without LF
2: With CR/LF
11118
n12
(342)
E
2
PROM write
selection
0: Write to RAM
and E
2
PROM
1: Write to RAM
only
1 0 132
n13
(145)
PU display
language
0: Japanese,
1: English,
2: German,
3: French,
4: Spanish,
5: Italian,
6: Swedish,
7: Finish
1
0
<1>
133
n14
(990) *
PU buzzer
sound control
0: Without
sound,
1: With sound
1 1 133
Communication Parameters
n15
(991) *
PU contrast
adjustment
0 (bright)
63 (dark)
1 58 134
Pammeter List