Paradyne 4200 Network Card User Manual


 
4. DS1 Facility Commands
4200-A2-GB20-00 August 2002
4-13
Response Format
If, in less than 2 seconds, a normal or error response cannot be sent, the following
acknowledgment response will be sent:
IP c
After the above response, a new command input may be generated.
Normal Response:
sid yy-mm-dd hh:mm:ss
M c COMPLD
/* RTRV-PM-T1:[tid]:aid_ds1:[ctag]::[monds1],[monlev],
[locn],,[tmper],[mondat],[montm] */
"aid_ds1,[aid_type]:monds1,monval,,[locn],,[tmper],
[mondat],[montm]"
;
Error Response:
sid yy-mm-dd hh:mm:ss
M c DENY
/*
RTRV-PM-T1:[tid]:aid_ds1:[ctag]::[monds1],[monlev],[locn],,
[tmper],[mondat],[montm] */
errcde
;
[mondat] Start date for the monitoring period. Valid values are:
mm-dd: Month and day
mm: Month (112)
dd: Day (131)
ALL: All performance monitoring data is retrieved
If no value is specified, today's date is assumed.
[montm] Start time for the monitoring period. Valid values are:
hh-mm: Hour and minute
hh: Hour (0023)
mm: Minute. Valid values are 0, 15, 30, and 45.
ALL: All performance monitoring data is retrieved
If no value is specified, the nearest value to the current time is
assumed. Grouping is allowed. Statistics will not be aligned with the wall
clock. Statistics will be monitored for the interval in which the selected
monitoring period falls.
Table 4-10. RTRV-PM-T1 Command Parameters (2 of 2)
RTRV-PM-T1:[tid]:aid_ds1:[ctag]::[monds1],[monlev],[locn],,
[tmper],[mondat],[montm];