Paradyne 4200 Network Card User Manual


 
C. Traps and MIBs
C-16
August 2002 4200-A2-GB20-00
ATM VCL Configuration Group (RFC 2515)
Contains configuration and state information of a bidirectional VCL at an ATM
interface. The atmVclEntry is supported as shown in Table C-7, VCL Configuration
MIB Group Objects.
Table C-7. VCL Configuration MIB Group Objects
Object Description Setting/Contents
atmVclOperStatus
(atmVclEntry
4)
Operational status of the VCL. Possible values are:
up(1): VCL is currently operational
down(2): VCL is currently not operational
unknown(3): The state of the VCL cannot
be determined.
atmVclLastChange
(atmVclEntry
5)
Contains the value of the sysUpTime
object at the time the VCL entered its
current operational state.
Integer. If the current state was entered into
prior to the last reinitialization of the agent,
then this object contains a zero value.
atmVccAalType
(atmVclEntry
8)
Identifies the type of AAL used with the
VCC.
The only valid values are:
aal5(3): AAL5
unknown(5): The AAL type cannot be
determined.
atmVccAal5CpcsTransmit
SduSize (atmVclEntry
9)
Contains the maximum Common Part
Convergence Sublayer SDU size
supported in the transmit direction of
this VCC.
Not supported.
atmVccAal5CpcsReceive
SduSize (atmVclEntry
10)
Contains the maximum Common Part
Convergence Sublayer SDU size
supported in the Receive direction of
this VCC.
Not supported.
atmVclEncapsType
(atmVclEntry
11)
Specifies the type of data encapsulation
used over the AAL5 Service Specific
Convergence Sublayer.
Not supported.