Paradyne 4200 Network Card User Manual


 
10. Fault Commands
4200-A2-GB20-00 August 2002
10-11
Example
Retrieve all service-affecting critical alarms for Network Termination Unit B.
RTRV-ALM-EQPT:TAMPA:NTB::CR,,SA;
TAMPA 02-06-27 03:38:43
M 42 COMPLD
/* RTRV-ALM-EQPT:TAMPA:NTB:42::CR,SA */
":NTB,EQPTS:CR,INT,SA,,,NEND,RCV,:Unknown error in
module"
;
Related Commands
None
cond_eqpt Equipment condition. Valid values are:
EQPT: Equipment failed self-test
FANALM-1: Fan alarm for fan 1
FANALM-2: Fan alarm for fan 2
PROGVER: Failed to load or find requested software or configuration
file
RMTDLFAIL: Failed to download software or configuration
SWROLLBACK: Software version rolled back
serveff As described for command parameters (see Table 10-5,
RTRV-ALM-EQPT Command Parameters), except that ALL is not used.
[cond_descr] Description of alarm condition
Table 10-6. RTRV-ALM-EQPT Response Parameters (2 of 2)
Parameter Explanation