13. Synchronization Commands
4200-A2-GB20-00 August 2002
13-3
Example
Configure the NE clock to use the local oscillator as its primary reference source.
ED-SYNCN:TAMPA:CLKSRCNT:42:::PRICREF=LOCAL;
TAMPA 01-12-20 11:20:34
M 42 COMPLD
/* ED-SYNCN:TAMPA:CLKSRCNT:42:::PRICREF=LOCAL*/
;
Related Commands
RTRV-SYNCN
on page 13-6
Table 13-2. ED-SYNCN Response Parameters
Parameter Explanation
tid Target NE identification
yy-mm-dd Year, month, and day
hh:mm:ss Hour, minute, and second
M Message generated in response to an input command
c If provided, ctag; otherwise 0
COMPLD Completed
DENY Input command is denied
/* */ Enclosed are human readable comments – unspecified format
errcde Error code (see Appendix A,
Error Codes
)