Paradyne 4200 Network Card User Manual


 
7. Equipment Commands
7-4
August 2002 4200-A2-GB20-00
REPT ALM EQPT
The REPT ALM EQPT message reports current alarms from the NE.
Table 7-3. REPT ALM EQPT Message Parameters
almcde atag REPT ALM EQPT aid_eqpts:ntfcde,cond_eqpt,
srveff,[ocrdat],[ocrtm]: [conddescr];
almcde Alarm code. Identifies the severity of the alarm. Values are:
*C: Critical alarm
**: Major alarm
*^: Minor alarm
A^: Automatic message (typically reports a cleared alarm)
atag Automatic tag. Indicates the numerical sequence of reported messages.
aid_eqpts Access identifier for the equipment. Each AID format can be preceded
with AID=, but this is not required. Enter in the following format,
replacing lower-case parameters with the values given:
LT-rack-shelf-slot: LT unit
SHELF-rack-shelf: shelf
rack: Rack Number (1)
shelf: Shelf Number (1)
slot: LT Slot Number (1)
[ntfncde] Notification code. Valid values are:
CR: Critical alarm
MJ: Major alarm
MN: Minor alarm
CL: Cleared alarm
cond_eqpt Equipment condition. Valid values are:
EQPT: Equipment failed self-test
FANALM-1: Fan alarm for fan 1
FANALM-2: Fan alarm for fan 2
PROGVER: Failed to load or find requested software
RMTDLFAIL: Failed to download software
SWROLLBACK: Software version rolled back
[serveff] Service effect. Valid values are:
SA: Service affecting
NSA: Not service affecting
[ocrdat] Date of alarm occurrence in the format mm-dd (month-day).
[ocrtm] Time of alarm occurrence in the format hh-mm (hour-minute).
[conddescr] Description of alarm condition (40 characters maximum).