Paradyne 4200 Network Card User Manual


 
6. Cross Connect Commands
4200-A2-GB20-00 August 2002
6-3
Normal Response:
sid yy-mm-dd hh:mm:ss
M c COMPLD
/* DLT-CRS-VC:[tid]:nt_vcl,lt_vcl:[ctag] */
;
Error Response:
sid yy-mm-dd hh:mm:ss
M c DENY
/* DLT-CRS-VC:[tid]:nt_vcl,lt_vcl:[ctag] */
aid:ERRCDE=errcde
/* error description */
;
Example
Delete VC-level cross-connection between Virtual Path 14, Virtual Channel 307
(network side) and Rack 1, Shelf 1, LT Slot 1, Circuit 4, Virtual Path 0, Virtual
Channel 63 (user side).
DLT-CRS-VC:TAMPA:NTVCL-14-307,LTVCL-1-1-1-4-0-63:42;
TAMPA 01-11-24 12:30:43
M 42 COMPLD
/* DLT-CRS-VC:TAMPA:NTVCL-14-307,LTVCL-1-1-1-4-0-63:42
*/
;
Related Commands
ED-CRS-VC
on page 6-4
ENT-CRS-VC
on page 6-7
RTRV-CRS-VC
on page 6-10
Table 6-2. DLT-CRS-VC Response Parameters
Parameter Explanation
tid Target NE identification
yy-mm-dd Year, month, and day
hh:mm:ss Hour, minute, and second
M Message generated in response to an input command
c If provided, ctag; otherwise 0
COMPLD Completed
DENY Input command is denied
/* */ Enclosed are human readable comments unspecified format
errcde Error code (see Appendix A,
Error Codes
)