Paradyne 4200 Network Card User Manual


 
9. Performance Commands
4200-A2-GB20-00 August 2002
9-11
Table 9-8. REPT-OPSTAT-VCL Response Parameters
Parameter Explanation
tid Target NE identification
yy-mm-dd Year, month, and day
hh:mm:ss Hour, minute, and second
M Message generated in response to an input command
c If provided, ctag; otherwise 0
COMPLD Completed
DENY Input command is denied
/* */ Enclosed are human readable comments unspecified format
errcde Error code (see Appendix A,
Error Codes
)
aid_vcl As described for command parameters (see Tabl e 9 -7,
REPT-OPSTAT-VCL Command Parameters).
[op_vcl] VCL operational parameters. Values are:
INCELLS: Rolling count of cells received on this VCL
OUTCELLS: Rolling count of cells transmitted on this VCL
LPBKINCELLS: A count of test cells received since the test started (up
to 2
32
-1)
LPBKOUTCELLS: A count of test cells received since the test started
(up to 2
32
-1)
LPBKRTDELAY: Average round trip delay in milliseconds since the test
has started. Only calculated on cells received; dropped cells are not
counted.
LPBKMNRTDELAY: Shortest round trip delay in milliseconds since the
test has started. Only calculated on cells received; dropped cells are not
counted.
LPBKMXRTDELAY: Longest round trip delay in milliseconds since the
test has started. Only calculated on cells received; dropped cells are not
counted.
LPBKTYPE: The type of OAM loopback test, if any, most recently
performed on the VCL:
E2E: End-to-End OAM cell
SEG: Segment OAM cell
NOTST: No test has been performed on the VCL
LPBKSEGID: The ATM segment location identifier for the segment
loopback or blank.
value Value of parameter specified by op_vcl