Paradyne 4200 Network Card User Manual


 
7. Equipment Commands
4200-A2-GB20-00 August 2002
7-7
Error Response:
sid yy-mm-dd hh:mm:ss
M c DENY
/* RTRV-EQPT:[tid]:aid_eqpts:[ctag] */
aid:ERRCDE=errcde
/* error description */
;
Table 7-6. RTRV-EQPT Response Parameters
Parameter Explanation
tid Target NE identification
yy-mm-dd Year (two digits), month, and day
hh:mm:ss Hour (00-23), minute, and second
M Message generated in response to an input command
c If provided, ctag; otherwise 0
COMPLD Completed
DENY Input command is denied
/* */ Enclosed are human readable comments unspecified format
errcde Error code (see Appendix A,
Error Codes
)
aid_eqpts As described for command parameters (see Table 7-5, RTRV-EQPT
Command Parameters), except that ALL, NT, and LT are not used
[eqpt_type] Type of equipment being installed (1 8 characters). Values are:
ADLT-A: 24-port ADSL (RV3) Line Termination card (main card)
ALTS-A: ADSL Line Termination shelf
ATUR-EP: ADSL endpoint [used for RTRV-INV-EQPT]
D1NT-A: DS1 Network Termination card
LPCO-A: 24-port Low Pass Central Office card
NONE: No equipment may be installed in this slot
If eqpt_type is not shown, the slot has not been configured.
[cur_eqpt] Type of the equipment actually installed (8 characters maximum). If the
equipment is not installed, no value is displayed.
[eqpt_nblk] Named parameter block for equipment. The block consists of one or
more of the following parameters, in any order separated by commas,
each followed by an equal sign and a valid value:
SWVER: Version of configured software (32 characters
maximum).
CURSWVER: Version of software actually installed (32 characters
maximum). If the equipment is not installed or no software is
available, no value is displayed.
DSPSWVER: The ADSL port DSP revision is displayed for the LT.
state State from the Bellcore state model. Values are: IS-NR, OOS-AU,
OOS-MA (transitory state, changes to OOS-AUMA), OOS-AUMA.
[sst] Secondary state of the equipment. Valid values are: AINS, FLT, PPS,
PWR, RAR, TS, UEQ.