Paradyne 4200 Network Card User Manual


 
13. Synchronization Commands
13-4
August 2002 4200-A2-GB20-00
RD-SYNCN
The RD-SYNCN Command retrieves the current reference source for
synchronization of the NE clock.
Response Format
If, in less than 2 seconds, a normal or error response cannot be sent, the following
acknowledgment response is sent:
IP c
After the above response, a new command input may be generated.
Normal Response:
sid yy-mm-dd hh:mm:ss
M c COMPLD
/* RD-SYNCN:[tid]:aid_syncn:[ctag][:] aid_syncn,cref */
;
Error Response:
sid yy-mm-dd hh:mm:ss
M c DENY
/* RD-SYNCN:[tid]:aid_syncn:[ctag][:] */
aid:ERRCDE=errcde
/* error description */
;
Table 13-3. RD-SYNCN Command Parameters
RD-SYNCN:[tid]:[aid_syncn]:[ctag][:];
Restrictions: All parameters in this command are position-defined.
[tid] Identification of the target NE. The default value is null. The NE SID
code is the only other valid value.
[aid_syncn] AID of the NE clock. The value is CLKSRCNT.
[ctag] Correlation tag (6 characters maximum) that links an input command
with associated output responses. The default is 0.