Paradyne 4200 Network Card User Manual


 
12. Security Commands
12-4
August 2002 4200-A2-GB20-00
ED-CID-SECU
The ED-CID-SECU command edits the configuration data associated with the
Channel Identifier (CID). The privilege codes associated with a CID define the
maximum privilege level of commands in each category (maintenance,
configuring, security, testing) that can be executed from that CID. Commands
requiring a higher privilege level are refused.
Response Format
If, in less than 2 seconds, a normal or error response cannot be sent, the following
acknowledgment response is sent:
IP c
After the above response, a new command input may be generated.
Table 12-3. ED-CID-SECU Command Parameters
ED-CID-SECU:[tid]:cid:[ctag]::chap:[cid_nblk];
RESTRICTIONS: All parameters in this command are position-defined. A maximum of
four remote (telnet) users and one Console terminal sessions can be active
simultaneously.
[tid] Identification of the target NE. The default value is null. The NE SID
code is the only other valid value.
cid Channel identifier. Grouping is allowed. Valid values are:
CRAFT: Local console interface
REMOTE: Remote console interface
[ctag] Correlation tag (6 characters maximum) that links an input command
with associated output responses.
chap Channel Access Privilege. Specifies the maximum access privilege for
commands on a channel. The only valid value is SUPER (maximum
user privilege).
[cid_nblk] Named parameter block for CID. The block consists of one or more of
the following parameters, in any order separated by commas, each
followed by an equal sign and a valid value. If not specified, the values
of these parameters remain unchanged.
MXINV: Maximum number of invalid logon alerts (3) before declaring an
intrusion alert.
TMOUT: Timeout interval for a user session, in minutes (099). If the
user is idle for this long, the session is automatically terminated. The
default is 10. A value of 0 disables the feature.