10. Fault Commands
4200-A2-GB20-00 August 2002
10-7
ntfncde As described for command parameters (see Table 10-3,
RTRV-ALM-ALL Command Parameters), except that ALL is not used.
cond Condition. Valid values are:
ACTLPBK: Facility placed in loopback.
AIS: Alarm Indication Signal
EQPT: Equipment failed self-test
FACTERM: Modem could not initialize
FANALAM-1: Alarm for Fan 1
FANALAM-2: Alarm for Fan 2
LCD: Loss of ATM cell delineation
LCD-F: Loss of cell delineation (fast)
LOF: Loss of Frame
LOL: Loss of Link
LOS: Loss of Signal/clock
LPR: Loss of Power
LORATE: Line rate is below planned rate (Loss of Signal Quality)
PROGVER: Failed to load or find requested software
RAI: Remote Alarm Indication
RMTDLFAIL: Failed to download software
SWROLLBACK: Software version rolled back
serveff As described for command parameters (see Table 10-3,
RTRV-ALM-ALL Command Parameters), except that ALL is not used.
[locn] As described for command parameters (see Table 10-3,
RTRV-ALM-ALL Command Parameters).
[dirn] As described for command parameters (see Table 10-3,
RTRV-ALM-ALL Command Parameters).
[cond_descr] Description of alarm condition
Table 10-4. RTRV-ALM-ALL Response Parameters (2 of 2)
Parameter Explanation