Paradyne 4200 Network Card User Manual


 
3. ADSL Facility Commands
3-38
August 2002 4200-A2-GB20-00
Response Format
If, in less than 2 seconds, a normal or error response cannot be sent, the following
acknowledgment response is sent:
IP c
After the above response, a new command input may be generated.
Normal Response:
sid yy-mm-dd hh:mm:ss
M c COMPLD
/*
RTRV-PM-ADSL:[tid]:aid_adsl:[ctag]::[monadsl],[monlev],
[locn],,[tmper],[mondat],[montm] */
"aid_adsl,{aidtype]:monadsl,monval,,locn,,tmper,
mondat,montm"
;
Error Response:
sid yy-mm-dd hh:mm:ss
M c DENY
/*
RTRV-PM-ADSL:[tid]:aid_adsl:[ctag]::[monadsl],[monlev],
[locn],,[tmper],[mondat],[montm] */
errcde
;
[montm] Start time for the monitoring period in the format hh-mm, where hh is
00-23 and mm is 0, 15, 30, or 45. Or enter ALL (all performance
monitoring data is retrieved). The default is the value nearest the
current time. Grouping is allowed.
Table 3-29. RTRV-PM-ADSL Command Parameters (2 of 2)
RTRV-PM-ADSL:[tid]:aid_adsl:[ctag]::[monadsl],[monlev],
[locn],,[tmper],[mondat],[montm];
Table 3-30. RTRV-PM-ADSL Response Parameters (1 of 2)
Parameter Explanation
tid Target NE identification
yy-mm-dd Year, month, and day
hh:mm:ss Hour, minute, and second
M Message generated in response to an input command
c If provided, ctag; otherwise 0
COMPLD Completed
DENY Input command is denied