Paradyne 4200 Network Card User Manual


 
15. Test Commands
4200-A2-GB20-00 August 2002
15-3
Error Response:
sid yy-mm-dd hh:mm:ss
M c DENY
/* OPR-LPBK-T1:[tid]:aid_ds1:[ctag]::,,,[lpbktype] */
aid:ERRCDE=errcde
/* error description */
;
Example
Place NTT1 circuit 1 in payload loopback mode.
OPR-LPBK-T1:TAMPA:NTT1-1:40::,,,PAYLOAD;
TAMPA 01-11-24 12:30:43
M 40 COMPLD
/* OPR-LPBK-T1:TAMPA:NTT1-1:40::,,,PAYLOAD */
;
Related Command
RLS-LPBK-T1
on page 15-7
Table 15-2. OPR-LPBK-T1 Response Parameters
Parameter Explanation
sid Source NE identification
yy-mm-dd Year, month, and day
hh:mm:ss Hour, minute, and second
M Message generated in response to an input command
c If provided, ctag; otherwise 0
COMPLD Completed
DENY Input command is denied
/* */ Enclosed are human readable comments unspecified format
errcde Error code (see Appendix A,
Error Codes
)