Paradyne 4200 Network Card User Manual


 
5. ATM Commands
4200-A2-GB20-00 August 2002
5-13
RTRV-ATMPORT
The RTRV-ATMPORT command retrieves configuration data associated with an
ATM port in the NE.
Response Format
If, in less than 2 seconds, a normal or error response cannot be sent, the following
acknowledgment response is sent:
IP c
After the above response, a new command input may be generated.
Normal Response:
sid yy-mm-dd hh:mm:ss
M c COMPLD
/* RTRV-ATMPORT:[tid]:aid_atmport:[ctag]::::[pstf][sstf]
*/
;
Table 5-11. RTRV-ATMPORT Command Parameters
RTRV-ATMPORT:[tid]:aid_atmport:[ctag]::::[pstf],[sstf];
RESTRICTIONS: All parameters in this command are position-defined.
[tid] Identification of the target NE. The default value is null. The NE SID
code is the only other valid value.
aid_atmport Access Identifier for an ATM port. The value can be preceded with
AID=, but this is not required. Grouping and ranging are allowed. Enter
any of in the following formats, replacing lower-case parameters with
the values given:
NTATM: ATM port in the NT
LTATM-1-1-slot-circuit: ATM port for an LT circuit
slot: LT slot number (1)
circuit: ADSL circuit on the LT (124)
[ctag] Correlation tag (6 characters maximum) that links an input command
with associated output responses. The default is 0.
pstf Primary State Filter. Valid values are:
IS: In Service
OOS: Out Of Service
sstf Secondary State Filter. The only valid value is LPBK (loopback).