Paradyne 4200 Network Card User Manual


 
13. Synchronization Commands
4200-A2-GB20-00 August 2002
13-7
Example
Retrieve the configuration of the reference source for synchronization of the NE
clock.
RTRV-SYNCN:TAMPA:CLKSRCNT:42;
TAMPA 01-12-20 11:20:34
M 42 COMPLD
/* RTRV-SYNCN:TAMPA:CLKSRCNT:42 */
CLKSRCNT::PRICREF=LOCAL;
Related Commands
ED-SYNCN
on page 13-2
Table 13-6. RTRV-SYNCN Response Parameters
Parameter Explanation
tid Target NE identification
yy-mm-dd Year, month, and day
hh:mm:ss Hour, minute, and second
M Message generated in response to an input command
c If provided, ctag; otherwise 0
COMPLD Completed
DENY Input command is denied
/* */ Enclosed are human readable comments unspecified format
errcde Error code (see Appendix A,
Error Codes
)
aid_syncn As described for command parameters
syncn_nblk Named parameter block for SYNCN. The block consists of the
parameter PRICREF (primary local refernce source for synchronizing
the clock), followed by an equal sign (=) and one of the following values:
LOOP = Loop timing recovered form the network-side facility
LOCAL = Local oscillator on NT board