Seiko FB-900 Printer User Manual


 
5-3
5. Bar code and enlarged character function
(2) Element width: DC4 DC4 E
Format: ASCII DC4 DC4 E n1 n2
Hex 14 14 45 n1 n2
Decimal 20 20 69 n1 n2
Function:
Specifies the n2/120 or n2/180 width of the element n1.
(1 n 2 127)
120 or 180 is specified with the DC4 DC4 D command.
n1 = 0: Narrow bar 3: Wide space
1: Wide bar 4: Inter-character gap
2: Narrow space
The narrow bar width or narrow space is used as the element width for
Code 93, Code 128, EAN-8, EAN-13, UPC-A, and UPC-E.
One element width of bar 1: Narrow bar width
One element width of space 1: Narrow space width
The midium bar or wide space width is used as the midium element width
for Code 11. The wide element width is (wide bar width x 2 - narrow bar
width).
This setting is not valid for Postnet.
The inter-character gap means the space between each set of codes of a bar
code which begins with a bar and ends with a bar.
(3) Bar code height: DC4 DC4 H
Format: ASCII DC4 DC4 H n
Hex 14 14 48 n
Decimal 20 20 72 n
Function: Sets the bar code height to n/12. (0 n 120)
The currently set line feed pitch serves as the bar code height when n
is set to 0. This setting is not valid for Postnet.
(4) Setting HRI on and off: DC4 DC4 I
Format: ASCII DC4 DC4 I n
Hex 14 14 49 n
Decimal 20 20 73 n
Function: Specifies whether or not to print an HRI. Also specifies the
HRI printing position if an HRI is to be printed.
n = 0: HRI not printed.
1: HRI printed below the bar code symbol.
2: HRI printed above the bar code symbol.
No HRI printed for Postnet or Element regardless of this setting.
See page 5-9.
Bar code function