5-4
— 5. Bar code and enlarged character function —
(5) HRI font: DC4 DC4 F
Format: ASCII DC4 DC4 F n
Hex 14 14 46 n
Decimal 20 20 70 n
Function: Selects the font of printing the HRI.
n = 0: Currently selected font
1: OCR-A
2: OCR-B
This setting is not valid for Postnet or Element.
(6) Check character: DC4 DC4 C
Format: ASCII DC4 DC4 C n
Hex 14 14 43 n
Decimal 20 20 67 n
Function: Specifies whether to add a check character automatically.
n = 0: No check character is added. (If a check character is needed, the
user must send bar code data.)
1: A check character is added. (The check character is not printed
in the HRI when Code 93 or Code 128 is selected.)
If the Codabar or Element is selected, no check character is added regardless of
this setting.
The following shows the methods of determining the check characters and bar
code types. (For details, see “Calculating the check character” below.)
Modulus 10 Industrial 2 of 5, Interleaved 2 of 5, Matrix 2 of 5, EAN, UPC,
Postnet
Modulus 11 Code 11 (Dual Check character)
Modulus 16 Codabar
Modulus 43 Code 39
Modulus 47 Code 93 (Dual Check character)
Modulus 103 Code 128
(7) Beginning of the bar code data sequence: ESC SI
Format: ASCII ESC SI
Hex 1B 0F
Decimal 27 15
Function: Indicates the beginning of a bar code data sequence.
Data between this and the end command of the bar code data sequence
is regarded as bar code data.
This command is valid only when #40 BARCODE/ENLARGED
CHAR is set to MODE 2 in the EXTENDED SETUP MODE.
See pages 5-12 and -13.
●
Bar code function