Seiko FB-900 Printer User Manual


 
Command
Control code
Corresponding setup function
Code
9-16
9. Software setup functions
Hexadecimal
HD + I + 1 + DC1 + n
(1B,7C,60,04,00,49,
(56) CD signal
(SERIAL I/F) (Setup Function #79)
31,11,n)H
n = 0
YES
(ENABLE)
1
NO
This setting becomes valid after the setup command mode
is terminated.
HD + I + 1 + DC2 + n
(1B,7C,60,04,00,49,
(57) DSR signal
(SERIAL I/F) (Setup Function #80)
31,12,n)H
n = 0
YES
(ENABLE)
1
NO
This setting becomes valid after the setup command mode
is terminated.
HD + I + b + n
(1B,7C,60,03,00,49,
(58) Input buffer size
(Setup Function #81)
62,n)H
n = 0 64K byte
1 8K byte
2 128 byte
This setting becomes valid after the setup command mode
is terminated.
HD + I + 0 + 0 + n
(1B,7C,60,04,00,49,
(59) BUSY/ACK signal timing
(PARALLEL I/F)
30,30,n)H (Setup Function #82)
n = 0
Type 3
1
Type 2
2
Type 1
This setting becomes valid after the setup command mode
is terminated.
HD + I + 0 + 1 + n
(1B,7C,60,04,00,49,
(60) Input data latch timing
(PARALLEL I/F)
30,31,n)H (Setup Function #83)
n = 0
Type F.
1
Type R.
This setting becomes valid after the setup command mode
is terminated.
See page 3-51.
See page 3-51.
See page 3-52.
See page 3-53.
See page 3-53.