9-15
— 9. Software setup functions —
●
Command
Control code
Corresponding setup function
Code
Hexadecimal
HD + I + 1 + 3 + n
(1B,7C,60,04,00,49,
(52) Protocol
(SERIAL I/F) (Setup Function #75)
31,33,n)H
n = 0 DTR
1 X-ON/X-OFF 1
2 X-ON/X-OFF 2
3 ETX/ACK
This setting becomes valid after the setup command mode
is terminated.
HD + I + 1 + 4 + n
(1B,7C,60,04,00,49,
(53) Baud rate
(SERIAL I/F) (Setup Function #76)
31,34,n)H
n = 0 38400 BPS
1 19200 BPS
2 9600 BPS
3 4800 BPS
4 2400 BPS
5 1200 BPS
6 600 BPS
7 300 BPS
This setting becomes valid after the setup command mode
is terminated.
HD + I + 1 + 5 + n
(1B,7C,60,04,00,49,
(54) Operation in case of serial error
(SERIAL I/F)
31,35,n)H (Setup Function #77)
n = 0
Print "❈"
1
Ignored
This setting becomes valid after the setup command mode
is terminated.
HD + I + 1 + DC0 + n
(1B,7C,60,04,00,49,
(55) CTS signal
(SERIAL I/F) (Setup Function #78)
31,10,n)H
n = 0
YES
(ENABLE)
1
NO
This setting becomes valid after the setup command mode
is terminated.
See page 3-49.
See page 3-49.
See page 3-50.
See page 3-50.