Chapter 5 Wipes
310
Basic Procedure for Wipe Settings
For an overview of the wipe modifiers, see “Wipe Pattern Variation and
Modifiers” (page 59).
Note that the available modifiers may depend on the pattern you are using. For
details, see “Possible combinations of wipe patterns and modifiers” (page
320).
Main pattern and sub pattern modifiers
You can make independent settings of the modifiers for the main pattern and
sub pattern.
To set the modifiers for the main pattern, in the M/E-1> Wipe menu, select
HF5 ‘Main Modify,’ and make the settings in the Main Modify menu.
To set the modifiers for the sub pattern, select HF6 ‘Sub Modify,’ and make
the settings in the Sub Modify menu.
Operations in the Main Modify menu and Sub Modify menu are the same.
Independently set modifiers for the main pattern and sub pattern
Positioner
Rotation
Aspect ratio
Pattern replication (MULTI)
•Pairing
Modulation
•Spring
•Spiral
The following sections show examples of modifying the main pattern.
Specifying the wipe direction (Direction)
You can specify the wipe direction (normal/reverse).
To specify the wipe direction in a menu
Use the following procedure.
1
In the M/E-1> Wipe menu, select HF4 ‘Edge/Direction.’
The Edge/Direction menu appears.
2
In the <Direction> group, specify the wipe direction.
Normal: regular direction
Normal/Reverse: alternate between regular and reverse for each transition
Reverse: reverse direction to normal