Sony 9000 Switch User Manual


 
Chapter 6 DME Wipes
336
Basic Procedure for DME Wipe Settings
3
In the <Position> group, press [Position], turning it on.
4
Set the following parameters.
Display indications when multiple channels are selected at the same
time
The indications on the knobs show the settings of the lowest-numbered
channel. When you turn the knobs to adjust the settings, this changes the
settings on the other channels by the same amount.
To return the DME wipe pattern position to the center of the screen
In the <Position> group, press [Center].
Displaying and moving the position of the DME wipe pattern
(position select)
Use the following procedure.
1
In the M/E-1>DME Wipe menu, select HF5 ‘Modify.’
The Modify menu appears.
In the <Position Select> group, the one of the [Top Left], [Top Right],
[Bottom Left], and [Bottom Right] buttons that is on indicates the current
display position of the DME wipe pattern.
2
In the <Position> group, press [Position], turning it on.
3
Depending on whether the DME wipe pattern is in one-channel mode or
two-channel mode, proceed as follows.
In one-channel mode: press [1st Ch], turning it on.
In two-channel mode: from the <Ch Select> group, select the
corresponding channel. You can select more than one channel at the
same time.
4
To move the position of the DME wipe pattern, press the button where you
want to move to, turning it on.
The DME wipe pattern displayed on the screen moves to the position of
the specified button.
Knob Parameter Adjustment Setting values
1 H Horizontal position 200.00 to +200.00
2 V Vertical position 200.00 to +200.00