Chapter 6 DME Wipes
332
Basic Procedure for DME Wipe Settings
Basic Procedure for DME Wipe Settings
You carry out DME wipe setting operations principally using the DME Wipe
menu for each of the M/E-1 to M/E-3 and PGM/PST banks.
This section describes the basic procedures for DME wipe settings, taking the
M/E-1>DME Wipe menu as an example.
For details of independent key transition DME wipe settings, see “DME Wipe
Settings for Independent Key Transitions” (page 339).
Note
To carry out DME wipes requires the BKDS-9470 DME Board Set.
DME Wipe Settings Menu
Accessing the DME Wipe menu
To access the M/E-1>DME Wipe menu, use any of the following operations.
• In the menu control block, select the top menu selection button [M/E 1], and
press VF6 ‘DME Wipe.’
• In the transition control block of the M/E-1 bank, press the transition type
selection button [DME] twice in rapid succession.
• In the Flexi Pad control block of the M/E-1 bank, press the [DME] button
twice in rapid succession.
Any of the above operations displays the M/E-1>DME Wipe menu.
DME Wipe Pattern Selection
You can select a DME wipe pattern in the DME Wipe menu, or by entering a
pattern number from the Flexi Pad control block.
Selecting a DME wipe pattern by a menu operation
Use the following procedure.
1
In the M/E-1>DME Wipe menu, select HF1 ‘1ch’ for one-channel mode
or HF2 ‘2ch’ for two-channel mode.