Black Box 8-port 10/100base-tx hardened ethernet extender switch Network Hardware User Manual


 
Page 161
724-746-5500 | blackbox.com
LB308A
Chapter 6: Command Line Console Management
The switch_a(config-if)# prompt will show on the screen.
switch_a(config)#interface fe1
switch_a(config-if)#
2. Usage:
Use switchport mode trunk command to set the switching characteristics of the
Layer-2 interface as trunk, and specify only tagged frames.
Use the no switchport trunk command to reset the mode of the Layer-2 interface
to access (default).
3. Command Syntax:
switchport mode trunk
no switchport trunk
4. Example:
The following example sets the switchport mode trunk of the interface fe1
(port 1):
switch_a(config)#interface fe1
switch_a(config-if)#switchport mode trunk
switch_a(config-if)#
Switchport hybrid allowed vlan:
1. Command Mode: Interface mode
Logon to Configure Mode (Configure Terminal Mode). Then logon to Interface
mode.
fe1 means port 1.
The switch_a(config-if)# prompt will show on the screen.
switch_a(config)#interface fe1
switch_a(config-if)#
2. Usage:
Use this command to set the switching characteristics of the Layer-2 interface to
hybrid. Both tagged and untagged frames will be classified over hybrid interfaces.
Use the no parameter to turn off allowed hybrid switching.