WSS# show radio-profile rp1
Beacon Interval: 100 DTIM Interval: 1
Max Tx Lifetime: 2000 Max Rx Lifetime: 2000
RTS Threshold: 2346 Frag Threshold: 2346
Long Preamble: no Tune Channel: yes
Tune Power: no Tune Channel Interval: 3600
Tune Power Interval: 600 Power ramp interval: 60
Channel Holddown: 300 Countermeasures: none
Active-Scan: yes RFID enabled: no
WMM Powersave: no QoS Mode: wmm
Service profiles: sp1
In this example, the QoS mode is WMM and U-APSD support (WMM powersave) is disabled.
(For more information about this command’s output, see the “AP Commands” chapter in the Nortel WLAN Security
Switch 2300 Series Command Line Reference.)
Displaying a service profile’s QoS settings
To display QoS settings and all other settings for a service profile, use the following command:
show service-profile {name | ?}
The following example shows the configuration of the sp1 service profile.
WSS# show service-profile sp1
ssid-name: corp2 ssid-type: crypto
Beacon: yes Proxy ARP: no
DHCP restrict: no No broadcast: no
Short retry limit: 5 Long retry limit: 5
Auth fallthru: none Sygate On-Demand (SODA): no
Enforce SODA checks: yes SODA remediation ACL:
Custom success web-page: Custom failure web-page:
Custom logout web-page: Custom agent-directory:
Static COS: no COS: 0
CAC mode: session CAC sessions: 14
User idle timeout: 180 Idle client probing: yes
Keep initial vlan: no Web Portal Session Timeout: 5
Web Portal ACL:
WEP Key 1 value: <none> WEP Key 2 value: <none>
WEP Key 3 value: <none> WEP Key 4 value: <none>
WEP Unicast Index: 1 WEP Multicast Index: 1
Shared Key Auth: NO
WPA enabled:
ciphers: cipher-tkip
authentication: 802.1X
TKIP countermeasures time: 60000ms
11a beacon rate: 6.0 multicast rate: AUTO
11a mandatory rate: 6.0,12.0,24.0 standard rates: 9.0,18.0,36.0,48.0,54.0
11b beacon rate: 2.0 multicast rate: AUTO
11b mandatory rate: 1.0,2.0 standard rates: 5.5,11.0
11g beacon rate: 2.0 multicast rate: AUTO
11g mandatory rate: 1.0,2.0,5.5,11.0 standard rates: 6.0,9.0,12.0,18.0,24.0, 36.0,48.0,54.0