Rev. 1.00, 05/04, page 177 of 544
9.6 Interrupt Sources
The free-running timer can request seven interrupts: ICIA to ICID, OCIA, OCIB, and FOVI. Each
interrupt can be enabled or disabled by an enable bit in TIER. Independent signals are sent to the
interrupt controller for each interrupt. Table 9.2 lists the sources and priorities of these interrupts.
Table 9.2 FRT Interrupt Sources
Interrupt Interrupt Source Interrupt Flag Priority
ICIA Input capture of ICRA ICFA High
ICIB Input capture of ICRB ICFB
ICIC Input capture of ICRC ICFC
ICID Input capture of ICRD ICFD
OCIA Compare match of OCRA OCFA
OCIB Compare match of OCRB OCFB
FOVI Overflow of FRC OVF Low
9.7 Usage Notes
9.7.1 Conflict between FRC Write and Clear
If an internal counter clear signal is generated during the state after an FRC write cycle, the clear
signal takes priority and the write is not performed. Figure 9.17 shows the timing for this type of
conflict.
φ
Address FRC address
Internal write
signal
Counter clear
signal
FRC N
H'0000
T
1
T
2
Write cycle of FRC
Figure 9.17 FRC Write-Clear Conflict