15.3.8 SERIRQ Control Registers 0 and 1 (SIRQCR0, SIRQCR1)
The SIRQCR registers contain status bits that indicate the SERIRQ operating mode and bits that
specify SERIRQ interrupt sources.
SIRQCR0
R/W
Bit Bit Name
Initial
Value
Slave Host Description
7 Q/C 0 R Quiet/Continuous Mode Flag
Indicates the mode specified by the host at the end of
an SERIRQ transfer cycle (stop frame).
0: Continuous mode
[Clearing conditions]
LPC hardware reset, LPC software reset
Specification by SERIRQ transfer cycle stop frame
1: Quiet mode
[Setting condition]
Specification by SERIRQ transfer cycle stop frame.
6 SELREQ 0 R/W Start Frame Initiation Request Select
Selects whether start frame initiation is requested when
one or more interrupt requests are cleared, or when all
interrupt requests are cleared, in quiet mode.
0: Start frame initiation is requested when all interrupt
requests are cleared in quiet mode.
1: Start frame initiation is requested when one or more
interrupt requests are cleared in quiet mode.
5 IEDIR 0 R/W Interrupt Enable Direct Mode
Specifies whether LPC channel 2 and channel 3
SERIRQ interrupt source (SMI, IRQ6, IRQ9 to IRQ11)
generation is conditional upon OBF, or is controlled only
by the host interrupt enable bit.
0: Host interrupt is requested when host interrupt enable
bit and corresponding OBF are both set to 1
1: Host interrupt is requested when host interrupt enable
bit is set to 1