Remote Maintenance by telnet
243
6
sntp
The printer clock can be synchronized with a NTP server clock using Simple Net-
work Time Protocol (SNTP). Use the “sntp” command to change SNTP settings.
View settings
msh> sntp
NTP server address configuration
You can specify the IP address of the NTP server.
msh> sntp server “IP_address”
Interval configuration
msh> sntp interval “polling_time”
You can specify the interval at which the printer synchronizes with the op-
erator-specified NTP server. The default is 60 minutes.
The interval can be entered from 0, or between 16 and 10,080 minutes.
If you set 0, the printer synchronizes with the NTP server only when you turn
the printer on. After that, the printer does not synchronize with the NTP server.
Time-zone configuration
msh> sntp timezone “+/-hour_time”
You can specify the time difference between the printer clock and NTP
server clock. The values are between –12:00 and +13:00.