HP (Hewlett-Packard) C737990900 Computer Drive User Manual


 
128 Drive Error Codes
Operating System (from 4400h)
Physical Formatter (from 4C00h)
4080h An access to a non-existent Tape Alert page was attempted.
4090h There is no usage data available in the Cartridge Memory.
4091h Usage pages are out of order and cannot be accessed.
4092h The last updated usage page has a CRC error. The data is invalid.
40A0h There is no mechanism sub-page data available in the Cartridge Memory.
40A1h The last updated mechanism sub-page has a CRC error. The data is invalid.
Error Description
4400h vGiveSem’ failed to signal a semaphore
Error Description
4C00h C1 has finished before C2 is ready for the dataset.
4C01h The physical formatter has been sent an invalid configuration name.
4C02h The physical formatter has been sent an invalid configuration value
4C03h C2 hardware is busy. The physical formatter C2 hardware is currently processing a
dataset.
4C04h The physical formatter C2 control DS0 register go bit is set.
4C05h The physical formatter C2 control DS1 register go bit is set.
4C06h The physical formatter C1 control register go bit is set.
4C07h The physical formatter CCQ Reader control register go bit is set.
4C08h The Read Chain Controller control go bit set. The physical formatter Read Chain Con-
troller control register go bit is set
4C09h Invalid write log channel number. The physical formatter has been asked for the error
rate log for a channel which does not exist
4C0Ah Invalid read log channel number. The physical formatter has been asked for the error
rate logs for a channel which does not exist.
Error Description