Parameters for the second motor have function codes of the form x2xx. They appear immedi-
ately after the first motor’s parameter in the menu listing order. The following table lists the
parameters that have the second parameter registers for programming.
Function Name
Parameter Codes
1st motor 2nd motor
Multi-speed frequency setting A020 A220
Acceleration time setting (Acceleration 1) F002 F202
Deceleration time setting (Deceleration 1) F003 F203
Second acceleration time setting (Acceleration 2) A092 A292
Second deceleration time setting (Deceleration 2) A093 A293
Select method to use 2nd acceleration/deceleration A094 A294
Acc1 to Acc2 frequency transition point A095 A295
Dec1 to Dec2 frequency transition point A096 A296
Level of electronic thermal setting B012 B212
Select electronic thermal characteristic B013 B213
Torque boost method selection A041 A241
Manual torque boost value A042 A242
Manual torque boost frequency adjustment A043 A243
V/F characteristic curve selection A044 A244
Base frequency setting A003 A203
Maximum frequency setting A004 A204
Select motor constant H002 H202
Motor capacity setting H003 H203
Motor poles setting H004 H204
Motor stabilization constant H006 H206