Hitachi L300P Power Supply User Manual


 
Parameter Settings for Keypad Entry
Appendix C
C–6
Fine Tuning
Functions
A098 Deceleration curve setting 00 00 00
A101 [OI]–[L] input active range start
frequency
0.00 0.00 0.00
A102 [OI]–[L] input active range end
frequency
0.00 60.00 0.00
A103 [OI]–[L] input active range start
current
20. 20. 20.
A104 [OI]–[L] input active range end
current
100. 100. 100.
A105 [OI]–[L] input start frequency
enable
01 01 01
A111 [O2]–[L] input active range start
frequency
0.00 0.00 0.00
A112 [O2]–[L] input active range end
frequency
0.00 0.00 0.00
A113 [O2]–[L] input active range start
voltage
–100. –100. –100.
A114 [O2]–[L] input active range end
voltage
100. 100. 100.
A131 Acceleration curve constants setting 02 02 02
A132 Deceleration curve constants setting 02 02 02
“A” Group Parameters Default Setting
User
Setting
Func.
Code
Name
-FE2 (Europe) -FU2 (USA) -FR (Japan)
“B” Group Parameters Default Setting
User Setting
Func.
Code
Name
-FE2 (Europe) -FU2 (USA) -FR (Japan)
B001 Selection of restart mode 00 00 00
B002 Allowable under-voltage power
failure time
1.0 1.0 1.0
B003 Retry wait time before motor restart 1.0 1.0 1.0
B004 Instantaneous power failure / under-
voltage trip alarm enable
00 00 00
B005 Number of restarts on power failure /
under-voltage trip events
00 00 00
B006 Phase loss detection enable 00 00 00
B007 Restart frequency threshold 0.00 0.00 0.00