Hitachi L300P Power Supply User Manual


 
“A” Group: Standard Functions
Configuring Drive
Parameters
3–10
NOTE: The base frequency must be less than or equal to the maximum frequency (ensure that
A003 A004).
A203 Base frequency setting,
2nd motor
Settable from 30 Hz to the
maximum frequency
✘ ✘ 50. 60. 60. Hz
>A203 2F-BASE
F 0060Hz
A004 Maximum frequency
setting
Settable from 30 Hz to
400 Hz
✘ ✘ 50. 60. 60. Hz
>A004 F-max
F 0060Hz
A204 Maximum frequency
setting, 2nd motor
Settable from 30 Hz to
400 Hz
✘ ✘ 50. 60. 60. Hz
>A204 2F-max
F 0060Hz
“A” Function
Run
Mode
Edit
Lo Hi
Defaults
Units
SRW Display
Func.
Code
Name Description
–FE2
(CE)
–FU2
(UL)
–FR
(Jpn)