Intel SBCEGBESW10 CLI Switch User Manual


 
QoS Commands
168 Intel® Blade Server Ethernet Switch Modules SBCEGBESW1 and SBCEGBESW10 CLI Guide
Default Configuration
There is no default configuration for this command.
Command Mode
Privileged EXEC mode
User Guidelines
If no keyword is specified, port QoS mode (for example., DSCP trusted, CoS trusted,
untrusted), default CoS value, DSCP-to-DSCP-mutation map attached to the port, and
policy map attached to the interface are displayed.
If no interface is specified, QoS information about all interfaces is displayed.
Example
The following example displays the buffer settings for queues on Ethernet port1.
Console# show qos interface ethernet 1 buffers
Ethernet 1
Notify Q depth
qid Size
1 125
2 125
3 125
4 125
5 125
6 125
7 125
8 125
qid Threshold
1 100
2 100
3 100
4 100
5 N/A
6 N/A