Intel SBCEGBESW10 CLI Switch User Manual


 
RMON Commands
212 Intel® Blade Server Ethernet Switch Modules SBCEGBESW1 and SBCEGBESW10 CLI Guide
User Guidelines
There are no user guidelines for this command.
Example
The following example displays the RMON event table.
The following table describes significant fields shown in the example:
show rmon log
The show rmon log Privileged EXEC mode command displays the RMON log table.
Syntax
show rmon log [event]
Parameters
event — Specifies the event index. (Range: 0-65535)
Console#
show rmon events
Index Description Type Community Owner Last time sent
----- -------------- -------- --------- ------- --------------------
1 Errors Log CLI Jan 18 2006 23:58:17
2 High Broadcast Log-Trap device Manager Jan 18 2006 23:59:48
Field Description
Index An index that uniquely identifies the event.
Description A comment describing this event.
Type The type of notification that the device generates about this event. Can have
the following values: none, log, trap, log-trap. In the case of log, an entry is
made in the log table for each event. In the case of trap, an SNMP trap is sent
to one or more management stations.
Community If an SNMP trap is to be sent, it is sent to the SNMP community specified by
this octet string.
Owner The entity that configured this event.
Last time sent The time this entry last generated an event. If this entry has not generated any
events, this value is zero.