Intel SBCEGBESW10 CLI Switch User Manual


 
RMON Commands
Intel® Blade Server Ethernet Switch Modules SBCEGBESW1 and SBCEGBESW10 CLI Guide 211
community text — If the specified notification type is trap, an SNMP trap is sent to
the SNMP community specified by this octet string. (Range: 0-127 characters)
description text — Specifies a comment describing this event. (Range: 0-127
characters)
name — Specifies the name of the person who configured this event. If unspecified,
the name is an empty string.
Default Configuration
This command has no default configuration.
Command Mode
Global Configuration mode
User Guidelines
If log is specified as the notification type, an entry is made in the log table for each event.
If
trap is specified, an SNMP trap is sent to one or more management stations.
Example
The following example configures an event identified as index 10 and for which the
device generates a notification in the log table.
show rmon events
The show rmon events Privileged EXEC mode command displays the RMON event
table.
Syntax
show rmon events
Default Configuration
This command has no default configuration.
Command Mode
Privileged EXEC mode
Console(config)# rmon event 10 log