Intel SBCEGBESW10 CLI Switch User Manual


 
SNMP Commands
242 Intel® Blade Server Ethernet Switch Modules SBCEGBESW1 and SBCEGBESW10 CLI Guide
if authentication and privacy are required, 36 bytes should be entered. Each byte in the
hexadecimal character string is two hexadecimal digits. Each byte can be separated by
a period or colon. (20 or 36 bytes)
Default Configuration
No group entry exists.
Command Mode
Global Configuration mode
User Guidelines
If auth-md5 or auth-sha is specified, both authentication and privacy are enabled for the
user.
When a
show running-config Privileged EXEC mode command is entered, a line for this
user will not be displayed. To see if this user has been added to the configuration, type the
show snmp users Privileged EXEC mode command.
An SNMP EngineID has to be defined to add SNMP users to the device. Changing or
removing the SNMP EngineID value deletes SNMPv3 users from the device’s database.
The remote engineid designates the remote management station and should be defined to
enable the device to receive informs.
Example
The following example configures an SNMPv3 user John in a group called user-group.
snmp-server engineID local
The snmp-server engineID local Global Configuration mode command specifies the
Simple Network Management Protocol (SNMP) engineID on the local device. To remove
the configured engine ID, use the
no form of this command.
Syntax
snmp-server engineID local {engineid-string | default}
no snmp-server engineID local
Console(config)#
snmp-server user
John user-group