802.1x Commands
386 Intel® Blade Server Ethernet Switch Modules SBCEGBESW1 and SBCEGBESW10 CLI Guide
dot1x re-authentication
The dot1x re-authentication Interface Configuration mode command enables periodic
re-authentication of the client. To return to the default configuration, use the
no form of
this command.
Syntax
dot1x re-authentication
no dot1x re-authentication
Default Configuration
Periodic re-authentication is disabled.
Command Mode
Interface Configuration (Ethernet)
User Guidelines
There are no user guidelines for this command.
Example
The following example enables periodic re-authentication of the client.
dot1x timeout re-authperiod
The dot1x timeout re-authperiod Interface Configuration mode command sets the
number of seconds between re-authentication attempts. To return to the default
configuration, use the
no form of this command.
Syntax
dot1x timeout re-authperiod seconds
no dot1x timeout re-authperiod
Console(config)# interface ethernet ext.16
Console(config-if)# dot1x re-authentication