Intel SBCEGBESW10 CLI Switch User Manual


 
Clock Commands
60 Intel® Blade Server Ethernet Switch Modules SBCEGBESW1 and SBCEGBESW10 CLI Guide
Syntax
sntp client poll timer seconds
no sntp client poll timer
Paramethers
seconds — Polling interval in seconds. (Range: 60-86400)
Default Configuration
Polling interval is 1024 seconds.
Command Mode
Global Configuration mode
User Guidelines
There are no user guidelines for this command.
Example
The following example sets the polling time for the SNTP client to 120 seconds.
sntp broadcast client enable
The sntp broadcast client enable Global Configuration mode command enables Simple
Network Time Protocol (SNTP) broadcast clients. To disable SNTP broadcast clients, use
the
no form of this command.
Syntax
sntp broadcast client enable
no sntp broadcast client enable
Default Configuration
The SNTP broadcast client is disabled.
Console(config)#
sntp client poll timer
120