Intel SBCEGBESW10 CLI Switch User Manual


 
RMON Commands
Intel® Blade Server Ethernet Switch Modules SBCEGBESW1 and SBCEGBESW10 CLI Guide 207
type — Specifies the method used for sampling the selected variable and calculating
the value to be compared against the thresholds. Possible values are
absolute and
delta.
If the method is absolute, the value of the selected variable is compared directly with
the thresholds at the end of the sampling interval. If the method is
delta, the selected
variable value of the last sample is subtracted from the current value, and the
difference is compared with the thresholds.
direction — Specifies the alarm that may be sent when this entry is first set to valid.
Possible values are
rising, rising-falling and falling.
If the first sample (after this entry becomes valid) is greater than or equal to rthreshold
and
direction is equal to rising or rising-falling, a single rising alarm is generated. If
the first sample (after this entry becomes valid) is less than or equal to
fthreshold and
direction is equal to falling or rising-falling, a single falling alarm is generated.
name — Specifies the name of the person who configured this alarm. If unspecified,
the name is an empty string.
Default Configuration
The type is absolute.
The startup direction is
rising-falling.
Command Mode
Global Configuration mode
User Guidelines
There are no user guidelines for this command.
Example
The following example configures the following alarm conditions:
Alarm index — 1000
Va ri a bl e identifier — Intel
Sample interval — 360000 seconds
Rising threshold — 1000000
Falling threshold — 1000000
Rising threshold event index — 10
Falling threshold event index — 20
Console(config)#
rmon alarm
1000 Intel 360000 1000000 1000000 10 20