Register 0x06: S/UNI-QUAD Channel Configuration
Bit Type Function Default
Bit 7 R/W AUTOPFEBE 1
Bit 6 R/W AUTOLFEBE 1
Bit 5 R/W AUTOLRDI 1
Bit 4 R/W AUTOPRDI 1
Bit 3 R/W Reserved 0
Bit 2 R/W Reserved 0
Bit 1 R/W Reserved 0
Bit 0 R/W Reserved 1
AUTOPRDI
The AUTOPRDI bit determines whether STS path remote defect indication
(RDI) is sent immediately upon detection of an incoming alarm. When
AUTOPRDI is set to logic one, STS path RDI is inserted immediately upon
declaration of several alarms. Each alarm can individually be enabled and
disabled using the S/UNI-QUAD Channel Path RDI Control Registers.
AUTOLRDI
The AUTOLRDI bit determines if line remote defect indication (RDI) is sent
immediately upon detection of an incoming alarm. When AUTOLRDI is set to
logic one, line RDI is inserted immediately upon declaration of several
alarms. Each alarm can individually be enabled and disabled using the S/UNI-
QUAD Channel Line RDI Control Registers.
AUTOPFEBE
The AUTOPFEBE bit determines if the path far end block errors are sent upon
detection of an incoming path BIP error events. When AUTOPFEBE is set to
logic one, one path FEBE is inserted for each path BIP error event,
respectively. When AUTOPFEBE is set to logic zero, incoming path BIP error
events do not generate FEBE events.
AUTOLFEBE
The AUTOLFEBE bit determines if line far end block errors are sent upon
detection of an incoming line BIP error events. When AUTOLFEBE is set to
logic one, one line FEBE is inserted for each line BIP error event, respectively.
When AUTOLFEBE is set to logic zero, incoming line BIP error events do not
generate FEBE events.